Femoral Radial Introducer Sheath 4 5 6 7Fr Intrakit access kit callouts Introducer Set

Femoral Radial Introducer Sheath 4 5 6 7Fr Intrakit access kit callouts Introducer Set

Disposable medical supplies interventional cardiology angiography sheath introducer set
Send Inquiry
Chat Now
Description
Technical Parameters
Product Description
Femoral Radial Introducer Sheath Set
1.Radiopaque Vessel Dilator
2.Radiopaque sheath with hemostasis valve and sideport with attached 3-way stopcock
3.Smooth atraumatic sheath and dilator transitions and a locking hub design make vessel entry and easy

4.Length can be customized


Mainly Usage
Used to intrude into the artery percutaneously in intervention surgery and establish a passageway for introducing catheters into the blood vessel.

[Product Structure] The product is composed of introducer sheath, dilator, guide wire, and seldinger needle. The product is made from polyethylene, polypropylene, and stainless steel.

 

[Product Type] 5F, 6F, 7F, 8F

 

[Application Scope] The introducer set and dilator enter into the vas along guidewire to build a passage, which connects skin and vas. After the dilator pulling out, the introducer sheath is the only entrance for the vas operation. The hemostasis valve of introducer set and the silica gel film at the hub is respectively used to stop blood stream and prevent seeping blood. It could avoid hemorrhage.

 

[Instruction for Use]

  • 1) Shave the skin, disinfect, spread the cloth and lay gauze aside.

  • 2) Puncture with seldinger needle from the top of the skin with angel between 30-45 degrees until bright

  • red blood gush from the hub of the seldinger needle to make sure the needle attains needed position.

  • 3) Insert the guidewire across the seldinger needle until the position needed.

  • 4) Hold guidewire tightly and then remove the seldinger needle.

  • 5) Insert dilator into the sheath, then insert guidewire from the end of dilator, hold tightly when the dilator is approaching the skin, and rotate gently while pushing into the vessel.

  • 6) Hold sheath tightly and remove guidewire and dilator.

  • 7) Translate catheter across the sheath into the vessel at needed position. If necessary, fix the sheath.

  • 8) After operating, remove the sheath and process hemostasis.

 

NOTE

Hold the guidewire anytime. According to the centimeter mark, adjust the insertion depth.

If widening percutaneous puncture is needed, do the operation with scalpel, its blade opposite to the guidewire.

 

Type I (Radial)
Ref. NO.Fr SizeSheathDilatorGuide WireNeedle
(G/mm)
I. D.
(mm)
L
(mm)
I. D.
(mm)
L
(mm)
O. D.
(inch)
TR015F1.91100.681680.02121/45
TR026F2.1110

 

 

Characteristic:

Type I (Radial)
1.Longer taper ensure smooth transition between sheath and dilator
2.Excellent pushability, flexibility and radiopacity
3.0.021” stainless steel guide wire, hydrophilic guide wire available upon request

 

Type II (Radial)
1.Longer taper ensure smooth transition between sheath and dilator
2.Excellent pushability, flexibility and radiopacity
3.Hydrophilic guide wire with cannula needle is available
4.Hydrophilic coated sheath available

 

Type III (Femoral)
1.Excellent pushability, flexibility and radiopacity
2.Smooth transition between sheath and dilator
3.No leakage under 80kpa
4.Hydrophilic coated sheath available

 

 

Verified Information

This information was Verified by  Intertek and is valid for the following period: 2020/12/31 --- 2021/12/30
The information below covers both the Gold Supplier and its related companies, which are defined according to china laws and regulations, and which will also be clearly displayed in the full report >>

The competitive advantage of product line:

The Company Can Supply Special Products According To Customers Requirements.

Production Capacity:

Product Line NameProduction Line CapacityActual Units Produced(Previous Year)
Infusion And Injection, Peripheral Intervention, Orthopedic Intervention, Cardiology Intervention.2000000 Pieces / Month;20000 Pieces / Month;20000 Pieces / Month;1000000 Pieces / Month10000000 Pieces;100000 Pieces;100000 Pieces;5000000 Pieces

Export Market Distribution:

MarketRevenue(Previous Year)Total Revenue (%)
North Americaconfidential12.0
South Americaconfidential5.0
Eastern Europeconfidential5.0
Southeast Asiaconfidential5.0
Africaconfidential2.0
Oceaniaconfidential1.0
Mid Eastconfidential5.0
Eastern Asiaconfidential5.0
Western Europeconfidential8.0
Central Americaconfidential5.0
Northern Europeconfidential5.0
Southern Europeconfidential1.0
South Asiaconfidential1.0
Domestic Marketconfidential40.0

Production Machinery:

Machine NameBrand & Model No.QuantityNumber of Year(s) UsedCondition
Injection Molding MachineConfidential501.0Acceptable
Pipe ExtruderConfidential51.0Acceptable
Ultrasonic Welding MachineConfidential501.0Acceptable
Automatic Packing MachineConfidential51.0Acceptable

Testing Machinery:

Machine NameBrand & Model No.QuantityNumber of Year(s) UsedCondition
Tension MachineConfidential11.0Acceptable
Video Measuring SystemConfidential51.0Acceptable
6% (Luer) Conical Joint Multifunction TesterConfidential21.0Acceptable
Gas ChromatographConfidential11.0Acceptable



Detailed 



1

1

2

3

4

6

7

Hot Tags: Femoral Radial Introducer Sheath 4 5 6 7Fr Intrakit access kit callouts Introducer Set, China, manufacturers, suppliers, factory, wholesale, cheap, low price,

正在输入中...

Your name
E-mail
Phone/WhatsApp
Message