Confocal Imaging - How To Make Cells Better in Glass Bottom Dishes

Oct 11, 2022 Leave a message


For common glass-bottom petri dishes on the market, a hole is usually made at the bottom of a plastic petri dish, and then a cover glass or cell slide with a thickness of 170-220 μm is glued to the bottom of the petri dish with shadowless glue or silica gel. Not the entire bottom of the petri dish is made of glass. The area suitable for observation is only in the area of the perforation. However, due to the hydrophobicity of glass, when culturing cells, the cells cannot adhere well to the glass, and the growth state is not good, and even the phenomenon of cell delamination occurs during confocal scanning imaging.

 

   In order for cells to adhere well, it is necessary to confirm that specific protein reagents have been coated before using glass bottom dishes for cell culture.

 

do-it-yourself quilt

 

     Different cell cultures require different coating reagents. At the same time, because the protein used for coating is a biological product, the product purity and dosage of the coating protein of different companies are different. This technical post is only for reference. The specific dosage of coating reagents should refer to the instructions of the brands used. . And it is best to do a gradient experiment with the reagents you use to find the most suitable coating concentration.

 

Here is an example of Poly-L-Lysine (PLL, sigma, P4832, 100μg/ml):

 

 PLL coating is suitable for the vast majority of cells, especially for the culture of neurons in the central system. It is necessary to make the protein content (μg/cm2) per unit area to reach the desired amount during use. The recommended amount of coating for PLL in this example is 2 μg/cm2. It is necessary to calculate the amount of protein required according to the coating area and coating volume.

 

 For example: 35mm glass bottom petri dish, the cell growth area is 3.5cm2, the coating area is 4.1cm2, and the volume of the coating solution is 400μl, then the recommended dosage is 2μg/cm2. Then 8.2 μg of PLL is needed in a single well. If only 400 μl of PLL solution is added, the concentration of PLL solution is 20.5 μg/ml (about 20 μg/ml). Therefore, the stock solution needs to be diluted with ultrapure water.

 

Specific steps:

 

1. Dilute the PLL stock solution 1:5 with ultrapure water.

 

2. Add 400 μl of PLL dilution to each 35 mm glass bottom petri dish.

 

3. Incubate for 1-2 hours at room temperature and aspirate the PLL dilution.

 

4. Carefully wash 3 times with 2ml of PBS solution or serum-free medium, and aspirate the wash solution.

 

5. Directly add the cell suspension for cultivation.

 

Method evaluation

 

    Due to the different properties of various coating proteins, different coating proteins are used in different ways. New contamination is often created due to the need to coat glass bottom dishes. Moreover, contamination is often discovered after the cells have been raised, which not only delays time, but also wastes kit consumables. After all, coated protein reagents and quality-assured glass-bottom dishes are expensive (glass-bottom dishes of poor quality may leak because the glue is not sticky or the glue used is toxic to cells).

 

Confocal Petri dishes without coating

 

      For children who want to save time and effort, it is more convenient to use confocal culture dishes without coating.

 

     Factors to consider when choosing a suitable culture dish are: whether it is suitable for your own cells to adhere to, whether the optical characteristics of the culture dish meet the confocal requirements.

 

     Petri dishes that meet the requirements of the above factors are not limited to coated glass bottom dishes. In fact, everyone knows that plastic dishes are cheaper and easier for cells to adhere to than glass. Here is an example of a confocal culture dish from Shanghai Jingan, to talk about the parameters that a culture dish that is suitable for confocal experiments needs to have:

 

It can be seen that the physical parameters of confocal culture dishes that meet the requirements of direct use are very close to glass, but at the same time, they also have hydrophilic properties, which can make most cells adhere better; and ductility are better than glass. It allows most cell lines and primary cells to directly adhere to the wall, and is not fragile, which is a good choice.

 

   You can also find the most suitable confocal culture dish for your experiment according to your specific experimental requirements and the parameters in the above table.

 

Method evaluation

 

     Choosing this type of petri dish does not require additional coating, greatly reducing the risk of contamination. And since the plastic bottom is easier to work with, no glue is needed to fix it to the bottom of the petri dish. Eliminate the possibility of leakage or cytotoxicity.